PERSONAL DOSIMETER DKG-21M MALAYSIA

Features

Stand-alone use or use within automated system of personal dosimetry control.
Storage of dose accumulation history in the nonvolatile memory with real time reference.
Transfer of dose accumulation history through the infrared port to the computer.
Blocking the mode of power supply switch off until the data reading procedure finished.
DER and DE threshold levels programming of gamma and X-ray radiation with the help of the computer or manually with control keys.
Blocking certain indication modes in response to the computer command.
Light and audio alarms when programmed threshold levels exceeded on DER and DE of gamma and X-ray radiation.
Display automatic switch off if current gamma background is lower than the preset threshold level with instant switching on at:
pressing any control key;
gamma background increase above the preset threshold level;
alarm clock ringing.
Periodic self-testing of batteries and detector.
Energy-compensated Geiger-Muller counter.
Specifications

Measurement ranges and main relative errors:

gamma and X-ray radiation individual dose equivalent rate HP(10)
0.1…1 000 000 µSv/h
(1…10 µSv/h; ±20%;10 µSv/h…1 Sv/h; ±10%)
gamma and X-ray radiation individual dose equivalent HP(10)
0.001…9 999 mSv ±15%
Energy range of detected gamma and X-ray radiation and energy dependence
0.05…6.0 MeV (0.05…1.25; ±25%)
Recording resolution of dose accumulation history in the nonvolatile memory
5…255 minutes
Time of data storage in the nonvolatile memory
not less than 10 years
Data exchange rate through infrared port
38 400 bit/s
Positive data exchange distance between the dosimeter and the infrared port adapter
not more than 0.3 m
Lithium battery (CR2450) life*
2 200 hours
Operating temperature range
-20…+50 °C
Weight
0.14 kg
Dimensions
56x96x16 mm

Category:

Description

Direct reading personal dosimeter in a damp and dustproof body with a high ingress protection rating, designed for use by the Army, Ministry of Emergencies and Civil Defense in conditions of significant temperature oscillations and high dustiness of atmosphere.

It can be used either independently or within the automated system of personal dosimetry control ASIDC-21.

The dosimeter allows storing dose accumulation history with real time reference in the non-volatile memory, and communicating it to the computer. If the programmed threshold levels of gamma dose or its rate are exceeded, light and audio alarms are actuated.